Displaying details for PROFINET devices

Further information about the subslots of a selected PROFINET device is displayed here.
Note
PROFIBUS DP connection
The SINUMERIK 828D only has one integrated PROFIBUS DP. The NC communicates with
the drives via this integrated PROFIBUS DP. It cannot be accessed from outside on the PPU
and is therefore not described further here.
Display
Device
Name
Number
IP address
Assignment
Communication state
Slots
No.
Subslot no.
I/O addr.
Type
Length (bytes)
Communication state
Machine axis
Telegr. type (NC)
SINUMERIK Operate
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3
Meaning/information
Name of the PROFINET device.
Number of the PROFINET device.
IP address of the PROFINET device.
Information as to whether the PROFINET device is assigned to the NC or
to the PLC.
Current communication state of the PROFINET connection to the device.
Green: The communication is active.
Red: The communication is not active.
Number of the slot.
Number of the subslot within the device.
I/O address in the I/O address space of the PLC assigned to this subslot.
For NC axes, the setpoint and the actual value must always be configured
on the same I/O address.
Specification, whether the subslot is an input, output or diagnostics slot.
If the subslot is assigned to an NC axis, then the output is always denoted
as setpoint and the input always as actual value.
Length of the I/O area reserved for the subslot in the STEP7 I/O address
space.
Actual communication state of the subslot
If a value is not available for the NC axes, then the display remains hidden.
Green: The communication is active.
Red: The communication is not active.
Gray: No NC axis.
Display of the name defined in the machine data for this slot
If the slot is not assigned to any NC axis, then the display remains hidden.
Displays the assigned telegram type
If a telegram type is not assigned in the NC machine data, then the display
remains hidden.
Service and diagnostics