Scope of delivery and requirements
1.4 Starting up the control
Selection
Create software backup
NCK default data
Drive default data
PLC default data
HMI default data
Factory settings
Delete OEM files
Delete user files
PLC stop
Checking the hardware
The technology is determined during startup for the SINUMERIK PPU 2xy.3. This distinction
is made using the article number found in the hardware information block, which is then
compared with the existing NCK scaling.
The following message is output if software that is not suitable for this hardware is found:
18
Function
A backup of the system CompactFlash card is saved to the user
CompactFlash card or USB FlashDrive.
The system loads the Siemens NCK data default settings and de‐
letes the retentive data on the PLC.
The SINAMICS user data is deleted.
PLC general reset and load default NOP PLC program.
Selection between two cases: No [Case 1]/ Yes [Case 2]
● Case 1:
User data in the /user directory is deleted.
● Case 2:
As case 1 and additionally:
Deletion of the data in the /oem and /addon directories - except
the logbook data.
Selection between two cases: No [Case 1]/ Yes [Case 2]
● Case 1:
The SINAMICS user data is deleted.
Siemens standard NCK data is loaded.
PLC general reset and load default NOP PLC program.
User data in the /user directory is saved.
● Case 2:
As case 1 and additionally:
Deletion of the data in the /oem and /addon directories - except
the logbook data.
All additional machine manufacturer data is deleted.
The PLC is stopped.
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3