Generating commissioning dialogs

2.3 Display on the user interface

2.3
Display on the user interface
Dialogs on the user interface
The following dialogs are available for the "Easy Extend" function:
● The control offers a configurable dialog, in which the available devices are shown.
● If first commissioning has not taken place yet, the control opens the commissioning dialog.
If a commissioning procedure (XML instruction: "START_UP") has been programmed, and the
device has still not been commissioned, then the control starts the commissioning procedure.
This involves a complete data backup before the series startup archives saved in the script
file are read in.
In the event of an error, the commissioning engineer can decide whether to roll back the
commissioning procedure or to rectify possible errors in machine configurations manually.
● Commissioning can be aborted early with the "Cancel" function. The control then copies
the previously saved commissioning files back.
If the machine has to be switched off after successful completion of the commissioning, the
XML statement "POWER_OFF" can be used to program that a corresponding message is
output on the control.