Tcp/Ip Diagnostics And Configuration - Siemens SINUMERIK 828D Commissioning Manual

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

4.4.2

TCP/IP diagnostics and configuration

The configuration of the network interfaces is displayed in the "TCP/IP Configuration" window.
Service
You use the service interface X127 for start-up and diagnostics.
A PG/PC communicates with the control via this interface as peer-to-peer. The IP address
192.168.215.1 is permanently set for the service interface.
Company network
The company network is used, for example, to access the network drives.
A PPU is connected to the company network via Ethernet interface X130.
Availability of the network connections
Network adapter connection
Availability
The availability describes the percentage of faulty packages compared to all the sent and
received packages.
Problems in the company network or the settling time during the start-up can cause fluctuations
in the availability.
Details of the network connections
● Computer name
The computer name of the control.
● DNS name
The name of the network adapter as stored in the DNS (Domain Name Service) server.
● MAC address
The physical address of the network adapter.
SINUMERIK Operate
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3
6.
Press the "Details" softkey to hide the detailed display.
7.
Press the "Return" softkey in order to exit the "TCP/IP Diagnostics" win‐
dow and return to the "PROFINET/PROFIBUS Diagnostics" window.
White
Network cable inserted
Red
Network cable not inserted
Green
Greater than 95%
Yellow
50 - 95%
Red
Less than 50%
Configuring the network
4.4 Station-related network diagnostics
41