General Settings - Siemens SINUMERIK 828D Commissioning Manual

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

Tool management
9.2 Configuring the user interface
Identifier <tag>
<DETAILSCONFIGURATION>
<MAGAZINEPLACENAMECONFIGURATION>
<MULTITOOLPLACETOOLTIPCONFIGURATION>
<PLACETYPECONFIGURATION>
<COORDSYSMAGAZINEASSIGNMENT>
<FILTERCONFIGURATION>
<LOADSTATIONSHANDLEALLTOOLS>
<CHANNELMAGAZINEASSIGNMENT>
<TOOLCHANGEREASON>
<IDENTCONNECTIONCONFIGURATION>
<SAVETOOLDATACONFIGURATION>
9.2.1

General settings

<SETTINGS> tag
The general settings for the tool management user interface are stored in the <SETTINGS>
tag.
Entries
ReactivateWithMagPos
ReactivateAllMonitorModes
ReactivateEnabled
CreateNewToolDialog
230
for the following setting:
Configuring the "Details" window (Page 266)
Assigning a name for magazines and magazine
locations (Page 269)
Configuring the "Assign Tooltips for Multitool Lo‐
cations" window (Page 271)
Assigning a name for magazine location types
(Page 271)
Assignment between magazines and magazine
locations and coordinate systems (Page 274)
Disabling the softkey depending on filters
(Page 276)
Configuring the "Load Station Selection" win‐
dow (Page 277)
Assignment of magazines and magazine loca‐
tions to channels (Page 273)
Reason for the tool change when reactivating
(Page 281)
Configure the code carrier connection
(Page 284)
Configuring Save to file (Page 287)
Meaning
True - reactivate with positioning of the tool to the tool mag‐
azine loading point.
False - default setting, reactivate without positioning the tool
magazine.
True - the actual values of all the monitoring types set in the
NC are reset.
False - default setting, actual value of the active monitoring
type is reset.
True - default setting, reactivation is enabled.
False - reactivation is disabled.
True - the "New Tool" window is displayed. In this window,
you can specify the tool name and the size of the tool (over‐
sized tool) before actually creating the tool. Other input op‐
tions can be defined by configuring the "New tool" window.
False - default setting, the "New Tool" window is not dis‐
played. Once the name has been entered, the tool will be
created directly in the tool list.
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3