Siemens SINUMERIK 828D Commissioning Manual page 882

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

Generating commissioning dialogs
2.6 Script language
Description
Identifier <tag>
AGM
DEVICE
NAME
START_UP
SET_ACTIVE
SET_INACTIVE
TEST
UID
VERSION
Negative acknowledgment of the function execution
With the automatically provided variable "$actionresult", the system can inform the XML parser
of a negative execution result. If the value is set to zero, the parser aborts the function
processing.
130
Meaning
Identifier for the "Startup Wizard"
Identifier for the description of the device.
Attributes:
● option_bit
The device is assigned a fixed bit number for the option
management.
The identifier specifies the name of the device to be displayed in the
dialog.
If a text reference is used, the dialog displays the text which is saved
for the identifier.
The identifier contains a description of the sequences required for
commissioning the device.
The identifier contains a description of the sequences required to
activate the device.
Attributes:
● timeout
The attribute permits a timeout to be specified in seconds. The
system interrupts processing if the script has still not been
completed after this time.
The identifier contains a description of the sequences required to shut
down the device.
Attributes:
● timeout
The attribute permits a timeout to be specified in seconds. The system
interrupts processing if the script has still not been completed after
this time.
The identifier contains the statements for testing the operating capa‐
bility of a device.
Attributes:
● timeout
The attribute permits a timeout to be specified in seconds. The system
interrupts processing if the script has still not been completed after
this time.
Unique numerical identifier to identify the device in the PLC ↔ HMI
interface.
Identifier for a version
Programming Manual, 10/2015, 6FC5397-3DP40-5BA3