4.1 Structure and elements of a dialog
Parameter:
Identifier
Header
Graphic
Dimension
System or user variable
Graphic position
Attributes
CM
CB
XG
AL
MC
42
Name of the dialog.
Dialog header as text or call for text (e.g. $85011) from a language-specific
text file.
Graphics file with path in double quotation marks.
Position and size of the dialog in pixels (distance from left-hand side, dis‐
tance from right-hand side, width, height), in relation to the upper left-hand
corner of the screen. The entries are separated by a comma.
System or user variable to which the current cursor position is assigned.
The NC or PLC can be provided with the cursor position via the system or
user variable. The first variable has the index 1. The order corresponds to
the configuration order of the variables.
Position of the graphic in pixels (distance from left-hand side, distance from
right-hand side), in relation to the upper left-hand corner of the dialog. The
entries are separated by a comma.
The specifications of the attributes are separated by a comma.
Possible attributes are:
Column mode: Column alignment
CM0
Default setting: The column distribution is carried out separately for each
line.
CM1
The column distribution of the line with the most columns applies to all lines.
CHANGE block: Response when dialog is opened: cb attributes specified
for a variable in a variables definition take priority over the default setting in
the dialog definition.
See also Behavior when opening the dialog (attribute CB) (Page 204).
CB0
Default setting: All CHANGE blocks associated with the dialog are pro‐
cessed when it is opened.
CB1
CHANGE blocks are then only processed if the relevant value changes.
Integration of an X3D animation as help display (only in the machining step
programming).
Example:
//M(Meas/
$85605/"myx3dhelpfile.hmi,,Z_Animation,,G17"///30,10/
XG1)
XG0
Default setting = 0
XG1
The screen attribute XG must already be set to 1 in the screen definition, a
change during runtime is not possible.
Note:
The specification in the screen property HLP must also be set accordingly.
The alignment of the screen header can be influenced with the screen at‐
tribute AL.
Example:
Central setting of the "Set password" window header:
//M(MY_PWD_SET/"Set password"//"EasyPwdModalLayout"//
AL2)
AL0
Left-justified, default
AL1
Right-justified
AL2
Centered
Screen background color (screen color)