Siemens SINUMERIK 828D Commissioning Manual page 590

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

Tool management
9.1 Machine data for tool management
MD28450 $MC_MM_TOOL_DATA_CHG_BUFF_SIZE
= 100
MD19320 $ON_TECHNO_FUNCTION_MASK
=2000000H
Bit 25 = 0 Tool monitoring function not enabled without magazine management.
Setting with magazine management
Make the following settings if you are commissioning the tool management with NC magazine
management:
MD18080 $MN_MM_TOOL_MANAGEMENT_MASK
= 13FH
Bit 0 = 1
Bit 1 = 1
Bit 6 = 0
Note
Machine data MD18080 can only be set for the technology variants cylindrical and surface
grinding.
MD20310 $MC_TOOL_MANAGEMENT_MASK
= 420FH
Bit 0 = 1
Bit 1 = 1
MD17530 $MN_TOOL_DATA_CHANGE_COUNTER
= 1FH
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
222
Number of entries in the buffer for the OPI change service for tool data. Dynamic memory
is used. This buffer is only created if either bit 2 or bit 3 is set in MD17530 $MN_TOOL_DA‐
TA_CHANGE_COUNTER.
Provide tool management data.
Provide monitoring data.
Magazines not divided into wear groups.
Magazine management active.
Monitoring functions of tool management active.
Tool status change.
Tool remaining unit quantity change.
Tool data change service.
Magazine data in the change service.
ISO data in the change service.
Buffer for changing tool data (DRAM).
Memory for the tool management is re‐
served step by step (SRAM).
Activating the tool management functions.
Marking the changed tool data for HMI.