Manufacturer and user cycle CUST_MEACYC.SPF

Function
The CUST_MEACYC.SPF is part of the measuring cycle functionality. It is called in every
measuring cycle before and after executing the measurement task. The CUST_MEACYC.SPF
acts in the same way when measuring in the JOG mode and measuring in the AUTOMATIC
mode.
SINUMERIK Operate
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3
Workpiece measurement: M0 for tolerance alarms 62304 oversize, 62305 undersize, 62306
permissible dimensional difference exceeded
Accept calibrated workpiece probe radius in the tool data.
For turning-milling technology, the calibration/measuring plane is different.
Repetitive measurement: tool measurement after a dimensional difference has been fallen
below (parameter _TDIF) and or confidence range (parameter _TSA)
Repetitive measurement: tool measurement with alarm and cycle stop at M0
Workpiece measurement: M0, after the permissible dimensional difference has been ex‐
ceeded
Tool measurement, milling tool: Spindle speed reduction at the last probing
Collision monitoring using workpiece probe for intermediate positioning
Coupling the spindle alignment with coordinate rotation in the active plane, for workpiece
measurement with multiprobe in the automatic mode
Direction of rotation of the spindle positioning for workpiece measurement regarding active
coupling of the spindle alignment with coordinate rotation in the active plane
For workpiece measurement, number of repeat measurements if the probe does not switch
Measuring feedrate for workpiece measurement
Retraction velocity from the measuring point for workpiece measurement
Workpiece measurement: probe activation/deactivation when positioning the spindle
Measure kinematics, scaling basis for the orientation vectors
Measure kinematics, measurement with active TRAORI or TCARR (CYCLE 800)
Workpiece measurement: calibration in the bore with known or unknown center point, meas‐
uring in JOG
Collision monitoring for tool measurement
For tool measurement, number of repeat measurements if the probe does not switch
Measuring feedrate for tool measurement
Retraction velocity from the measuring point for tool measurement
7.9 Measuring cycles and measurement functions
Measuring cycles function screen
Configuring cycles
173

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents