Advertisement

Requirement
You have already made the settings from the following section:
See also: Measuring cycles and measurement functions, general (Page 170)
Settings
General cycle setting data
SD54760 $SNS_MEA_FUNCTION_MASK_PIECE
Bit 1
Bit 3
Bit 4
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 16
Bit 17
Bit 18
Bit 19
Bit 20
Bit 21
Bit 22
Bit 24
Bit 25
Channel-specific cycle setting data
SD55630 $SCS_MEA_FEED_MEASURE
= 300
SINUMERIK Operate
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3
Display select softkey 3D measurement
Enable probe calibration field to be selected
Select calibration input measuring feed
Enable ZO to be selected in the basis reference (SETFRAME)
Enable ZO to be selected in the channel-specific basis frame
Enable ZO to be selected in the basis frame
Enable ZO to be selected in the adjustable frame
Enable ZO, coarse and fine, to be selected
Select tool offset, geometry and wear
Select tool offset, not inverted and inverted
Select tool offset L1, R or L1, L2, L3 R
Select tool offset, zero offset (_TZL)
Select tool offset, dimensional difference monitoring (_TDIF)
Select workpiece measurement with spindle reversal
Selects align workpiece probe in the switching direction
Select number of measurements (_NMSP)
Select offset with mean value generation (_TMV)
Select experience values (_EVNUM)
Select total setting-up offset
Select calibration to unknown or to known center point
Select calibration with/without position deviation
Select zero offset when measuring the angulation of the spindle
Measuring feedrate when calibrating the workpiece probe
7.9 Measuring cycles and measurement functions
Settings for the input screen, measuring
cycles in AUTOMATIC, workpiece meas‐
urement.
1)
1)
Measuring feedrate [mm/rev]
Configuring cycles