Tool management
9.2 Configuring the user interface
● Both channels are assigned TO unit 1.
Channel 1:
Channel 2:
● Each channel is assigned a toolholder.
Channel 1:
Channel 2:
Figure 9-1
268
MD28085 $MC_MM_LINK_TOA_UNIT
= 1
The channel is assigned TO unit 1.
MD28085 $MC_MM_LINK_TOA_UNIT
= 2
The channel is assigned TO unit 1.
MD20124 $MC_TOOL_MANAGEMENT_TOOLHOLDER
= 1
The channel is assigned toolholder 1.
MD20124 $MC_TOOL_MANAGEMENT_TOOLHOLDER
= 2
The channel is assigned toolholder 2.
Magazine configuration
Assigns TO unit to a channel (SRAM)
Assigns TO unit to a channel (SRAM)
Toolholder number
Toolholder number
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3