The PPU variant PPU 24x.3 BASIC only has one PROFINET connection (PN).
Note
PROFIBUS DP connection
The SINUMERIK 828D only has one integrated PROFIBUS DP. The NC communicates with
the drives via this integrated PROFIBUS DP. It cannot be accessed from outside on the PPU
and is therefore not described further here.
Display
Status
Bus status
Bus configuration
S7 subnet ID
Baud rate
Cycle time
Sync. Component (TDX)
PROFIBUS diagnostics/devices
Device name
Device no.
Assignment
Communication state
SINUMERIK Operate
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3
Meaning/information
POWER_ON (0): Status after the control is switched on.
OFFLINE (1): A basic initialization has been performed.
STOP (2): Start in accordance with the hardware configuration (SDB).
CLEAR (3): The PROFINET devices have been parameterized and con‐
figured in accordance with the hardware configuration (SDB) and taken
into the cyclic data exchange with zero output data.
OPERATE (4): The cyclic data exchange with the PROFINET devices is
running.
ERROR (9): A fatal error had been detected (e.g. invalid or faulty SDB).
(<n>) Corresponds to the OPI variable value for the bus state.
S7 subnet ID of the PROFINET subnet
Transmission rate in Mbd
Configured bus cycle time in ms; defines the position control cycle clock
at the same time.
Configured interval in ms for the cyclic data exchange within a PROFINET
cycle.
Name of the PROFINET device.
Number of the PROFINET device.
Information as to whether the PROFINET device is assigned to the NC or
to the PLC.
NC: e.g. one or more drives controlled by the NC.
PLC: e.g. I/Os or an axis controlled by the PLC, NC/PLC.
Information as to whether the PROFINET device is identified on the bus
via the communication state.
Green: The PROFINET device has been detected on the PROFINET
and the data exchange is working error-free with the assigned component
(NC and/or PLC).
Red: Incorrect response / no communication
Service and diagnostics