Tool management
9.3 NC ↔ PLC user interface
DB4300...43xx
Signals from tool management [r]
DBBy108
Acknowl‐
edgment
step 7
DBBy109
Acknowl‐
edgment
step 15
DBBy110
Acknowl‐
edgment
step 23
DBBy111
Reserved
DBBy112
Multitool: Location number (INT)
y [= 0 or 1]: TO unit 1 or TO unit 2
xx: Tool holder
Feedback signals: Signal description
Signal description:
● Acknowledgment OK (DB43xx.DBX100.0): Positive feedback of acknowledgment status.
The acknowledgment of the PLC user program (area DB42xx.DBB0 to DBB3) was
transferred without error to the tool management. This signal is reset after one PLC cycle.
● Acknowledgment error (DB43xx.DBX100.1): Negative feedback of acknowledgment
status.
There is an error in the acknowledgment of the PLC user program (area DB42xx.DBB0 to
DBB3). The cause of the error is displayed in "Error status".
The "acknowledgment error" bit is only set if the acknowledgment from the PLC firmware
is accepted as error free and the tool management detects and signals an error in the
acknowledged tool transfer (for example, when the target location for tool transfer is
occupied).
Errors that are detected directly by the tool management in the NC before an
acknowledgment is sent by the PLC user program, do not result in the setting of bit 100.1.
If an error is present that prevents transfer of the acknowledgment to the tool management
(error status 1 to 7), the error is only output on the interface of the tool management and
not by the NC (no NC alarm!).
If necessary, signal such errors with a user PLC alarm in the PLC user program.
This signal remains pending statically until the error has been acknowledged (set the bit
"Reset acknowledgment error" DB4200.DBX9.0) by the user. The interface in
DB42xx.DBB0 to DBB3 is disabled if bit "acknowledgment error" is pending. Incoming
acknowledgment bits are not evaluated by the PLC firmware and are also cleared when bit
"Reset acknowledgment error" is set.
● Multitool: Location number
Multitool: Location number that the PLC user program entered as active location number
when acknowledging in the acknowledgment interface.
278
Acknowl‐
Acknowl‐
edgment
edgment
step 6
step 5
Acknowl‐
Acknowl‐
edgment
edgment
step 14
step 13
Acknowl‐
Acknowl‐
edgment
edgment
step 22
step 21
Acknowl‐
Acknowl‐
edgment
edgment
step 30
step 29
Acknowl‐
Acknowl‐
Acknowl‐
edgment
edgment
edgment
step 4
step 3
step 2
Acknowl‐
Acknowl‐
Acknowl‐
edgment
edgment
edgment
step 12
step 11
step 10
Acknowl‐
Acknowl‐
Acknowl‐
edgment
edgment
edgment
step 20
step 19
step 18
Acknowl‐
Acknowl‐
Acknowl‐
edgment
edgment
edgment
step 28
step 27
step 26
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3
Acknowl‐
Acknowl‐
edgment
edgment
step 1
step 0
Acknowl‐
Acknowl‐
edgment
edgment
step 9
step 8
Acknowl‐
Acknowl‐
edgment
edgment
step 17
step 16
Acknowl‐
Acknowl‐
edgment
edgment
step 25
step 24
CNC commissioning