Preconditions
Access to the "Customize softkeys" is protected using a general MD51073
$MNS_ACCESS_SET_SOFTKEY_ACCESS. This machine data is pre-assigned access level
3, i.e. the function is available from "Service" password and higher. In order that an operator
with "User" access level can use this function, this machine data should be set to a value > 3.
An external mouse is required in order to make changes.
Changing the access level of a softkey
Procedure:
1. In the "Start-up" operating area, select the "HMI" menu.
2. On the expansion bar ">>" select the "Customize softkeys" softkey.
You can obtain precise information about the procedure in the following dialog.
1. Confirm with "OK", in order to activate the "Customize the softkey access levels active"
mode. A table is displayed.
2. Select an operating area.
3. Place the mouse cursor on a softkey and using the right-hand mouse key call the context
menu "Define access level", in order to define a new access level for this softkey.
– The displayed access level is the default setting.
– A softkey is practically made invisible with "Always hide".
– You can reset the additionally allocated access level using "Original setting". This
4. In order to accept changes, return to the "Start-up" operating area and there, press the
"Close customizing" softkey. This means that you exit the "Customize the softkey access
levels active" mode.
If you acknowledge the following query with "OK", then the changes are accepted and
become effective once the system has rebooted.
5. If the changes to a softkey are not to be applied, select the line and press the "Original
setting" softkey. This means that in the "New access level" column, the "Original setting"
identifier is entered, which functions in the same way as deletion. This entry is no longer
available following a system restart. "
Example
The following access levels were changed:
Softkey
SISuMainScreenMenuHu::0::3
SIMaJogMillMenuHU::jogHuMore::6
SISuPaUserDataMenu::::4
Once selected, the identifier and position of the softkey are transferred to the "Softkey" column.
SINUMERIK Operate
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3
selection is only listed after an individual access level was set.
General settings
1.1 Access levels
New access level
Manufacturer