Powering The Ipbl - Avaya DECT R4 Installation And Administration Manual

Hide thumbs Also See for DECT R4:
Table of Contents

Advertisement

Installing and operating the IPBS and IPBL

Powering the IPBL

The IPBL power supply connector is located at the rear. The power supply feeds both the IPBL
and the connected RFPs. The IPBL is powered with 110/230 VAC, 60/50 Hz.
A 4A fuse protects the 110/230VAC (100 – 240 VAC) power input against overload.
The IEC 60320 type C14 (male) connector consists of:
One - Live lead
Two - neutral lead
Three - Protective earth lead
Installing the IPBL
1. Install the IPBL in the standard 19-inch rack.
2. Connect the synchronization cables and the RFP cable as necessary.
3. Attach the power cable to a wall socket with protected earth and switch on the IPBL.
4. Connect the cables in the following order:
Ethernet cable (A) LAN1 port must be used (LAN2 port is for administration only).
If you enable RSTP, both the ports are utilized by the system. See
IPBL)
on page 142
Synchronization cable (ring sync, reference sync) (B)
Base station cable (RFP cable)
Note:
The connected RFPs must not be connected to protective earth.
Note:
5. Monitor the total current consumption from the GUI.
6. Ensure that the current consumption does not exceed the following values:
Max current consumption is 1,9/0,9 A when supplied with 110/230 VAC.
92
Avaya DECT R4 - Installation and Maintenance Guide
1
2
3
Enabling RSTP (only for
02/2016