Installing and operating the IPBS and IPBL
To scan for occupied system IDs of other Avaya IP-DECT systems within the coverage area,
perform an RFP scan following the steps below.
Note:
Executing an RFP scan will terminate all calls on the IPBS/IPBL.
Note:
1. Select Diagnostics > RFP Scan
2. Click Start Scanning
Service Report
To download a service report do the following:
1. Select Diagnostics > Service Report.
2. Click download.
3. Click Save and browse where to save the service report.
Environment
This section only applies to the IPBL. The Environment tab gives information power supply and
consumption. It also displays the temperature and the fan status.
1. Select Diagnostics > Environment.
The following information is available in the Power section:
Power supply - AC or DC power port.
Voltage - input voltage.
Current consumption - total consumption for the IPBL an the connected RFPs.
Max 4,0 A when supplied with AC power port
Max 5,2 A when supplied with DC power port
The following information is available under the Environment tab:
•Temperature - °C
•Fan status - OK, not OK

Reset

Some configuration changes requires a reset in order to take effect. A reset reboots the
software. There are two ways to perform a reset:
Idle reset - waits until there are no active calls in the IPBS/IPBL.
Immediate reset - clears all calls and resets the IPBS/IPBL.
190
Avaya DECT R4 - Installation and Maintenance Guide
02/2016