Technical Data
Storage temperature
Enclosure protection:
Immunity to electromagnetic fields:
Immunity to ESD:
Accelerated Life Testing
Climate stress
Drop test
Vibration test
Chemical stress
Keypad actuation test
Squeeze test
Free fall test, ATEX/IECEx product
3
Accessories
Hinge-type/Swivel-type clip
Desktop charger, Basic
Desktop charger, Advanced
Battery pack opener
Charging Rack
Verified Bluetooth Headsets
Nokia BH-201/804/904
SonyEricsson HBH-GV435
SonyEricsson HBH-PV740
Jabra BT530
Jabra GO 660/6430/6470
Jabra Supreme
1. Note that storing Li-Ion batteries at high temperature dramatically reduces its capacity. For example, storage
around maximum temperature reduces the capacity with 20% in less than a month, permanently.
640
Avaya DECT R4 - Installation and Maintenance Guide
1
:
-20°C to +60°C
IP65
3V/m EN61000-4-3
8 kV contact discharge and 16 kV air discharge
(EN61000-4-2)
Handset exposed for quick temperature changes (-40 °C
to 75 °C) 25 times. Handset dwelt on each temperature
during 40 minutes.
Handset dropped 30 times from 1,2 metres
Handset exposed for vibrations during 2,5 hours
Handset exposed for Oleic Acid
Keys pressed 15 000 times with a force of 13N
Handset squeezed 1000 times with a force of 130N.
IEC 68-2-32, procedure 1, dropped 12 times from 1 metre,
specification extended to 2 metres.
ATEX/IECEx-classified headset adaptor for standard Peltor
headset and ATEX/IECEx-classified Peltor headset.
3
Plantronics Voyager 510/520/835/PRO/PRO+
Plantronics Discovery 925/975
Plantronics Explorer 240/390/395
Plantronics M20/M25/M50/M55/M1100
Plantronics Marque 2 Backseat GO
Peltor M2RX7-WS4
2
, IEC EN60529
02/2016