Avaya DECT R4 Installation And Administration Manual page 256

Hide thumbs Also See for DECT R4:
Table of Contents

Advertisement

Configuring Avaya Aura
Configuring the signaling group
The IP trunk's signaling group needs to have the node name of the Master IPBS as Far-end
Node Name.
There is a strong linkage between the signaling group and the related trunk group. When
creating the signaling group before the trunk group is available, the fields Trunk Group for
NCA TSC, Trunk Group for Channel Selection, and X-Mobility/Wireless Type have to be left
blank. After the trunk group is created change the Trunk Group for NCA TSC, Trunk Group
for Channel Selection to the number of the new trunk group and X-Mobility/Wireless Type
should be DECT.
The Near-end Listen Port needs to match the Master IPBS IP Trunk setting "CS Port". The
Far-end Listen Port needs to match the Master IPBS Trunk setting "Local Port".
Note:
Do not use port 5022 as Local Port or Far-end Listen Port. It is already used
Note:
internally on the Communication Manager side.
Max number of NCA TSC and Max number of CA TSC should be set to 1 or higher. The
Enable Layer 3 Test should be set to "y" for IP trunk supervision.
For Communication Manager 4
display signaling-group 9
Group Number: 9
IP Video? n
Trunk Group for Channel Selection: 9
TSC Supplementary Service Protocol: a
Near-end Node Name: procr
Near-end Listen Port: 6000
LRQ Required? n
RRQ Required? n
Media Encryption? n
DTMF over IP:
Link Loss Delay Timer(sec): 90
Enable Layer 3 Test? y
256
Avaya DECT R4 - Installation and Maintenance Guide
®
Communication Manager
SIGNALING GROUP
Group Type: h.323
Remote Office? n
T303 Timer(sec): 10
In-band
Max number of NCA TSC: 1
Max number of CA TSC: 1
SBS? n
Trunk Group for NCA TSC: 9
X-Mobility/Wireless Type: DECT
Network Call Transfer? 1
Far-end Node Name: Master IPBS_110
Far-end Listen Port: 6000
Far-end Network Region: 1
Calls Share IP Signaling Connection? n
Bypass If IP Threshold Exceeded? n
H.235 Annex H Required? n
Direct IP-IP Audio Connections? y
IP Audio Hairpinning? n
Interworking Message: PROGress
DCP/Analog Bearer Capability: 3.1kHz
Page
1 of
5
02/2016