Avaya DECT R4 Installation And Administration Manual page 541

Hide thumbs Also See for DECT R4:
Table of Contents

Advertisement

At power-up or restart of the Elise 2 Server (AIWS Hardware), the relay is released until the
applications are working properly. If the relay is released longer, Elise 2 Server (AIWS
Hardware) is malfunctioning.
RS232 Communication with external unit
Figure 178: The Elise 2 Server (AIWS Hardware) has three identical RS232 connectors; J7, J8
and J11. Depending on software application the RS232 ports can be used or not. How to connect
external equipment to the Elise 2 Server (AIWS Hardware) is described in the documentation of
the software application. In
Hardware) is described.Description of the Elise 2 Server (AIWS Hardware) RS232 ports.
Connections for Serial Line Printer
To connect the serial line printer, see
Figure 179: Connections for serial line printing.
25-pin male
D-sub connector
DTR
20
6
DSR
8
DCD
2
TXD
3
RXD
7
GND
4
RTS
5
CTS
Avaya DECT R4 - Installation and Maintenance Guide
figure
178, the RS232 connectors on the Elise 2 Server (AIWS
figure 179
for the pin-layout and wiring run.
ELISE
J11/J7/J8
1 (not used)
2 TX
3 RX
4 CTRL IN
5 CTRL OUT
6 (not used)
7 GND
8 (not used)
Installation
541
02/2016

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents