Installation Test Procedure - Avaya DECT R4 Installation And Administration Manual

Hide thumbs Also See for DECT R4:
Table of Contents

Advertisement

Installing Elise 2 Server (AIWS Hardware)
4. To be able to access Elise 2 Server (AIWS Hardware) from a PC, the PC has to belong to
the same network as Elise 2 Server (AIWS Hardware) or Elise 2 Server (AIWS
Hardware)'s IP address has to be found in the PC's route table. To facilitate this, the
program "Route to ELISE" is provided.
Start the program "Route to ELISE". Press "Attach" to add the Elise 2 Server (AIWS
Hardware) network setup IP address to the route table.
5. Press "Launch config". This will open the page "192.5.36.229/system" in your browser.
The user ID is "admin" and the default password is "changeme".
6. Press "System Setup" and navigate to "Network". Set the network parameters. Use the
on-line help if any problems occur.
7. Navigate to "System 900" and select the bus operating mode for the module. The modes
are described in the on-line help.
8. Change the default passwords for all users. If the passwords are not changed, anyone
with knowledge of the default passwords can access your Elise 2 Server (AIWS Hardware)
and change any parameter.
9. Set all sections in SW3 to OFF. Reboot Elise 2 Server (AIWS Hardware) by navigating to
"Reboot".
10. Return to the program "Route to ELISE" and press "Detach" to remove the Elise 2 Server
(AIWS Hardware) network setup IP address from the route table. Close the program.
11. When Elise 2 Server (AIWS Hardware) has been restarted, enter the URL xxx.xxx.xxx.xxx/
admin in your browser (xxx.xxx.xxx.xxx is the IP address that was given to Elise 2 Server
(AIWS Hardware) during network setup) and see that it has started up correctly.
12. If an entry is added in the DNS, it will be easier to connect to Elise 2 Server (AIWS
Hardware).

Installation test procedure

1. If the Elise 2 Server (AIWS Hardware) is connected to a Central Unit, the indicator will light
steadily green within 90 seconds.
If the indicator continues to flash orange, check:
Connections on Elise 2 Server (AIWS Hardware)
Elise 2 Server (AIWS Hardware) has a correct System 900 address
Check in the AIWS advanced configuration > system information of all applications are
running.
Check if the following are connected: Time synchronizer, DECT interface, SMS center.
Check at the DECT DH (Device handler) whether the Nr. of DM (Device Managers) is
more than 0.