Important:
For installation on ships the 12 - 24 V DC input should be used to meet the
Important:
regulatory requirements for safety and EMC. (To meet the regulatory
requirements for EMC alone, the 12 - 24 V DC input should be used on deck,
bridge and in special power distribution zones while 100 - 240 V AC input can be
used in general power distribution zones).
Primary power supply 100-240 V AC
Connect supply voltage to the 100-240 V AC jack as shown in figure:
Figure 201: 100-240 V AC
Connect the external power supply to the 12-24 V DC screw connector.
Figure 202: 12-24 V DC connection to external supply
Changing power supply parameters
By default, the Elise 3 Server (AIWS2 Hardware) is configured to use the primary power supply
(100-240 V AC). If you connect the module to an external battery, you must configure
accordingly from the Advanced Configuration page. If the parameter setting conflicts with the
actual setup, the Power LED will indicate with slow flashing red light.
1. Select Other Settings > Advanced Configuration in the menu on the Configuration page.
2. Select Power supply in the menu on the Advanced Configuration.
Avaya DECT R4 - Installation and Maintenance Guide
Installing the Elise 3 Server (AIWS2 Hardware)
100-240 VAC
12-24 VDC
+
-
577
02/2016