Honda CR-V 1997 Service Manual page 547

Table of Contents

Advertisement

II]
Position
Line pressure (1) flows to the manual valve and the modulator valve. Line pressure (1) changes to line pressure (4) and
1st-hold
clutch
pressure
at
the manual
valve,
and
changes
to modulator pressure at
the
modulator valve. Modulator pres-
sure
(6)
flows to the left
ends
of the '-2 shift valve and 3-4
shift
valve because
shift
control
solenoid
valve A is turned OFF
by the
PCM.
The
1-2 shift valve and the 3-4 shift valve are moved to the right side. Line pressure (4) becomes 1st
clutch
pressure (10)
at
the 1-2 shift valve. 1st
clutch
pressure (10)
is
applied to the 1st
clutch,
and the 1st clutch is
engaged.
lst-
hold clutch pressure (18) flows to the 1st-hold clutch via the 3-4 shift valve
and
the '-2 shift valve. Power is transmitted
only during deceleration through the 1st-hold
clutch.
NOTE:
When
used, "left"
or
"right"
indicates direction on the hydraulic circuit.
• The hydrauliC
circuit
shows the
'97
- 98 models (7 positions); the '99
-
00 models (6 positions)
is
similar.
(cont'd)
14-31