IP Multicast Commands

configure pim register-rate-limit-interval

configure pim register-rate-limit-interval <time>
Description
Configures the initial PIM-SM periodic register rate.
Syntax Description
time
Specifies an interval time in seconds. Range is 0 - 60. Default is 0.
Default
Default is 0.
Usage Guidelines
Configuring a non-zero interval time can reduce the CPU load on the first hop in case register stop
messages are not received normally.
If a non-zero value is configured, the first hop switch would send register messages only at
second
time
intervals. The default value is zero, which sends continuos register messages. This command takes effect
only until the register stop message is not received, in other words, when the register suppression timer
is not running.
Example
The following command configures the initial PIM register rate limit interval:
configure pim register-rate-limit-interval 2
History
This command was first available in ExtremeWare 6.2.2.
This command was added to the Summit "e" series of switches in ExtremeWare 7.2e.
Platform Availability
This command is available on all platforms.
1970
ExtremeWare 7.5 Command Reference Guide