unconfigure inline-power power-supply

unconfigure inline-power power-supply
unconfigure inline-power power-supply
Description
Sets the power supply mode to the default setting of redundant mode.
NOTE
This command is available only for the Summit 300-48 switch.
Syntax Description
This command has no arguments or variables.
Usage Guidelines
The Summit 300-48 PoE subsystem supports dual power supplies for either redundant or load-sharing
modes. Redundant mode is the default and provides hitless PoE should one of the two power supplies
fail, be removed, or powered off. Load-sharing mode allows both power supplies to provide power to
the PoE system, providing greater PoE power capacity. For load-sharing operation, the amount of power
provided to the PoE system is the sum of the power supplied by the power supplies.
Example
The following command returns a Summit 300-48 switch to redundant power supply mode:
unconfigure inline-power power-supply
History
This command was first available in ExtremeWare 7.3e
Platform Availability
This command is available on the Summit 300-48 switch only.