Extreme Networks ExtremeWare Command Reference Manual page 2320

Version 7.5
Hide thumbs Also See for ExtremeWare:
Table of Contents

Advertisement

Power Over Ethernet Commands—Summit 300 and 400-24p Switches and Alpine PoE Module
• PD Class
• Max Allowed Power
• Measured Power
• Line Voltage
• Discovered Resistance
• Discovered Capacitance
• Current
• Fault Status
Example
The following command displays summary inline power information for port 1:
show inline info port 1:*
Following is sample output from this command:
Port State
Class
1:1
searching -----
The following command displays detail inline power information for port 1:
show inline info detail port 1:1
Following is sample output from this command:
Configured Admin State: Enabled
Inline Power State: searching
MIB Detect SStatus: searching
Violation Precedence: max-class-operator
Operator Limit: 15400 milliwatts
Reserved Power: 0 milliwatts
Inline Type: other
Connect Order: none
Max Allowed Power: 0.0 W
Measured Power: 0.0 W
Line Voltage: 0.0 Volts
Discovered Resistance: 0.0K ohms
Discovered Capacitance: 0 uF
Fault Status: None
History
This command was first available in ExtremeWare 7.2.
This command was added to the Summit "e" series of switches in ExtremeWare 7.3e.
2320
Connect
Volts
History
0
0.0
Lable:
Detection: auto
PD Class:
Current: 0 mA
Curr
Res
Power
(mA)
(Kohms) (Watts)
0
0.0
0.00
Fault
0
ExtremeWare 7.5 Command Reference Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Extremeware 7.5