unconfigure inline-power backup-source slot

unconfigure inline-power backup-source slot
unconfigure inline-power backup-source slot <slot_number>
Description
Resets the backup power source to its default for the specified slot. Does not take effect until the power
is cycled on the slot.
NOTE
This command is available only for the Alpine FM-32Pi PoE Module.
Syntax Description
slot_number
Specifies the slot for which the backup power source will be reset to its default.
Default
Internal
Usage Guidelines
This command resets the backup power source that was configured with the following command:
configure inline-power backup-source [internal | none] slot <slot_number>
Resetting the backup power source to its default for the specified slot does not take effect until the
power is cycled on the slot.
Example
The following command resets the backup power source to its default for slot 1:
unconfig inline-power backup-source slot 1
History
This command was first available in ExtremeWare 7.2.