configure inline-power power-supply

configure inline-power power-supply [redundant | load-sharing]
Description
This command selects the power supply operating mode.
NOTE
This command is available only for the Summit 300-48 switch.
Syntax Description
redundant
load-sharing
Default
Redundant mode
Usage Guidelines
The PoE subsystem on the Summit 300-48 switch supports dual power supplies for either redundant or
load-sharing modes. Redundant mode is the default and provides hitless PoE should one of the two
power supplies fail, be removed, or powered off. Load-sharing mode allows both power supplies to
provide power to the PoE system, providing greater PoE power capacity. For load-sharing operation,
the amount of power provided to the PoE system is the sum of the power supplied by the power
supplies. With load-sharing, all PoE devices may experience a power hit if a power supply fails.
Example
The following command configures a Summit 300-48 switch for redundant power supply mode:
configure inline-power power-supply redundant
History
This command was first available in ExtremeWare 7.3e.
Platform Availability
This command is available only on the Summit 300-48 switch.
ExtremeWare 7.5 Command Reference Guide
Specifies redundant power supply mode.
Specifies load-sharing mode.