Power Over Ethernet Commands—Summit 300 and 400-24p Switches and Alpine PoE Module

show inline-power

show inline-power
Description
Displays inline power status information for the system.
NOTE
This command is available only for the Alpine FM-32Pi PoE Module and the Summit 300-48 switch.
Syntax Description
This command has no arguments or variables.
Default
N/A
Usage Guidelines
The output indicates the following inline power status information for the system:
• System maximum inline power—The nominal power available, in watts.
• Configured System Power Usage—The configured power usage threshold for the system, shown in
watts and as a percentage of available power.
The output indicates the following inline power status information for each slot:
• Main PSU Status—The operational status of the main power supply unit. The status conditions are:
— ON: Power is being provided to the PoE controller.
— OFF: Power is not being provided to the PoE controller.
— FAULT: An error has occurred.
• Backup PSU Status—The condition of the backup power device, indicated by the following
information:
— State: Present, Not Present, Fault
— Status: ACTIVATED, DEACTIVATED
Valid State/Status combinations are:
• Present, ACTIVATED
• Present, DEACTIVATED
• Not Present
• Fault
• Firmware Status—The condition of the firmware, indicated by one the following states:
— Initializing—Firmware is still coming up.
— Operational—Firmware is up and running.
— Download failure—Firmware failed to download properly.