Configure Inline-Power Detection - Extreme Networks ExtremeWare Command Reference Manual

Version 7.5
Hide thumbs Also See for ExtremeWare:
Table of Contents

Advertisement

configure inline-power detection

configure inline-power detection [auto | discovery-test-only] ports
<portlist>
Description
Sets the power detection mechanism on the specified ports.
NOTE
This command is available only for the Alpine FM-32Pi PoE Module and the Summit 300-48 switch.
Syntax Description
auto
discovery-test-only
portlist
Default
Auto
Usage Guidelines
This command controls the power detection mechanism on the specified ports. Test mode forces power
discovery operations; however, power is not supplied to detected PDs.
Example
The following command forces automatic power discovery operations and specifies that power will be
supplied to detected PDs for ports 4 – 6 on slot 3:
configure inline-power detection auto ports 3:4-3:6
History
This command was first available in ExtremeWare 7.2.
This command was added to the Summit "e" series of switches in ExtremeWare 7.3e.
Platform Availability
This command is available only on Alpine FM32-Pi PoE Modules and the Summit 300-48 switch.
ExtremeWare 7.5 Command Reference Guide
Forces automatic power discovery operations and specifies that power will be supplied to
detected power devices (PDs) for the specified ports.
Forces power discovery operations and specifies that power will not be supplied to
detected PDs for the specified ports.
Specifies one or more slots and ports. On a modular switch, can be a list of slots and
ports. On a stand-alone switch, can be one or more port numbers. May be in the form 1, 2,
3-5, 1:*, 1:5, 1:6-1:8.
configure inline-power detection
2281

Advertisement

Table of Contents
loading

This manual is also suitable for:

Extremeware 7.5

Table of Contents