ALARM FACILITY TEMPERATURE LED

alarm facility temperature led
Overview
Use this command to make the fault LED flash if the switch's temperature goes
above the high limit for any of its monitored temperature thresholds. To see the
limits, use the command
Use the no variant of this command to remove this alarm.
Syntax
alarm facility temperature led
no alarm facility temperature led
Default
By default, there are no alarms
Mode
Global Configuration
Usage notes
You can also use a relay to trigger an external alarm output, such as a buzzer, by
using the command
Example
To flash the LED if the switch overheats, use the commands:
awplus#
awplus(config)#
To remove that alarm, use the commands:
awplus#
awplus(config)#
Related
alarm facility temperature relay
commands
show alarm facility settings
show alarm facility status
show system environment
Command
Version 5.4.9-1.1: input-member and output-member parameters added on
changes
IE510-28GSX switches
C613-50644-01 Rev B
show system
alarm facility temperature
configure terminal
alarm facility temperature led
configure terminal
no alarm facility temperature led
Command Reference for IE220 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
environment.
relay.