Ip Irdp Holdtime - Allied Telesis IE220 Series Manual

Industrial ethernet layer 2+ switches, command reference for alliedware plus version 5.5.3-0.x
Table of Contents

Advertisement

IP A
P
DDRESSING AND
ROTOCOL

IP IRDP HOLDTIME

ip irdp holdtime
Overview
This command sets the maximum length of time that the advertised addresses are
to be considered as valid router addresses by hosts.
The no variant of this command resets the holdtime back to the default of 1800
seconds.
Syntax
ip irdp holdtime <0-9000>
no ip irdp holdtime
Default
The IRDP holdtime is set to 1800 seconds (30 minutes) by default.
Mode
Interface Configuration for a VLAN interface or a local loopback interface.
To set the holdtime value of addresses advertised on vlan2 to 4000 seconds, use
Examples
the following commands:
awplus#
awplus(config)#
awplus(config-if)#
To set the holdtime value of addresses advertised on vlan2 back to the default,
use the following commands:
awplus#
awplus(config)#
awplus(config-if)#
Related
show ip irdp interface
commands
C613-50644-01 Rev B
C
OMMANDS
Parameter
Description
<0-9000>
The holdtime value in seconds of addresses advertised.
configure terminal
interface vlan2
configure terminal
interface vlan2
Command Reference for IE220 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
ip irdp holdtime 4000
no ip irdp holdtime
844

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ie220-6ghxIe220-10ghx

Table of Contents