Mep Crosscheck - Allied Telesis IE220 Series Manual

Industrial ethernet layer 2+ switches, command reference for alliedware plus version 5.5.3-0.x
Table of Contents

Advertisement

C
F
M
ONNECTIVITY
AULT
ANAGEMENT

MEP CROSSCHECK

mep crosscheck
Overview
Use this command within the MD instance context to create a Remote MEP
instance and configure its parameters.
Use the no variant of this command to destroy the Remote MEP instance.
Syntax
mep crosscheck mpid <rmep-id> ma-name <ma-name> [mac
<HHHH.HHHH.HHHH>]
no mep crosscheck mpid <rmep-id> ma-name <ma-name>
Mode
Ethernet CFM Configuration
Usage notes
Maintenance Points are entities that exist within an MD/MA and can perform the
CFM/802.1ag functions such as Continuity Checks for fault management. The main
type of MP is a Maintenance End Point (MEP). This type of maintenance point sits
at the edges of a Maintenance Domain but is a member of only one MA within the
Maintenance Domain. Thus an MEP is used at the end of a VLAN segment, or it is
used at the end of a link. MPs live on bridge ports and station ports. On a bridge
port, there are two types.
C613-50644-01 Rev B
C
OMMANDS
Parameter
mpid
<rmep-id>
ma-name
<ma-name>
mac
<HHHH.HHHH.HHHH> Specify the Remote MEP's MAC address using the
An Up Maintenance Entity is considered an inward MP. It communicates
across the inside of the bridge to the other side, and this allows it to reach the
outside world. It lives on a bridge port for a given VLAN, but it does not use
this port to send or receive to get to the outside world. Instead, it sends and
receives through the inside of the bridge and communicates to the outside
world through the other VLAN port members. An Up MP cannot be used for
Link Level CFM.
A Down Maintenance Entity is considered an outward MP. It sends and
receives only through its bridge port outwardly to the outside world, and
does not communicate inside the bridge. A Down MP is not subject to
blocking due to Spanning Tree Protocol (STP) or any other protocol trying to
prevent loops in the network. As such, it is important that Down MPs be used
Command Reference for IE220 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
Description
Specify the Remote MEP id.
1-8191. This must be unique ID for all MEPs in the MA (both
local and remote).
Specify the Maintenance Association that the Remote MEP is
to be associated with.
Specify the Maintenance Association's CLI instance name.
Optionally, when using unicast for communication between a
Local MEP and a Remote MEP, specify the remote MEP's MAC
address.
HHHH.HHHH.HHHH format where H is a hexadecimal value.
331

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ie220-6ghxIe220-10ghx

Table of Contents