A
M
C
LARM
ONITORING
OMMANDS
8032
ALARM FACILITY G
LED
alarm facility g8032 led
Overview
Use this command to make the fault LED flash if one or more G.8032 ERP instances
are in the PROTECTION state.
Use the no variant of this command to remove this alarm.
Syntax
alarm facility g8032 led
no alarm facility g8032 led
Default
By default, there are no alarms
Mode
Global Configuration
Usage notes
You can also use a relay to trigger an external alarm output, such as a buzzer, by
using the command
Example
To flash the LED if one or more G.8032 ERP instances are in the PROTECTION state,
use the commands:
awplus#
awplus(config)#
To remove that alarm, use the commands:
awplus#
awplus(config)#
Related
alarm facility g8032 relay
commands
show alarm facility settings
show alarm facility status
Command
Version 5.4.9-1.1: output-member parameter added on IE510-28GSX switches
changes
C613-50644-01 Rev B
alarm facility g8032
configure terminal
alarm facility g8032 led
configure terminal
no alarm facility g8032 led
Command Reference for IE220 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
relay.
482