SHOW POWER
INLINE COUNTERS
Table 2: Parameters in the show power-inline counters command output
Related
clear power-inline counters interface
commands
show power-inline
show power-inline interface
Command
Version 5.4.8-0.2: added to x550 series products
changes
C613-50644-01 Rev B
Parameter
Description
Interface
The PoE port(s) in the format port1.0.z, where z is the port
number. After the port number, "/D" indicates the data pair and
"/S" indicates the spare pair.
MPSAbsent
The number of instances when the PoE MPS (Maintain Power
Signature) signal has been lost. The PoE MPS signal is lost when a
PD is disconnected from the PSE. Also increments
pethPsePortMPSAbsentCounter in the PoE MIB.
Overload
The number of instances when a PD exceeds its configured power
limit (as configured by the
increments pethPsePortOverLoadCounter in the PoE MIB.
Short
The number of short circuits that have happened with a PD. Also
increments pethPsePortShortCounter in the PoE MIB.
Invalid
The number of times a PD with an Invalid Signature (where the PD
has an open or short circuit, or is a legacy PD) is detected. Also
increments pethPseInvalidSignatureCounter in the PoE
MIB.
Denied
The number of times a PD has been refused power due to power
budget limitations for the PSE. Also increments
pethPsePortPowerDeniedCounter in the PoE MIB.