Flowcontrol Hardware (Asyn/Console) - Allied Telesis IE220 Series Manual

Industrial ethernet layer 2+ switches, command reference for alliedware plus version 5.5.3-0.x
Table of Contents

Advertisement

U
A
C
SER
CCESS
OMMANDS
(
FLOWCONTROL HARDWARE
ASYN

flowcontrol hardware (asyn/console)

Overview
Use this command to enable RTS/CTS (Ready To Send/Clear To Send) hardware
flow control on a terminal console line (asyn port) between the DTE (Data Terminal
Equipment) and the DCE (Data Communications Equipment).
flowcontrol hardware
Syntax
no flowcontrol hardware
Mode
Line Configuration
Default
Hardware flow control is disabled by default.
Usage notes
Hardware flow control makes use of the RTS and CTS control signals between the
DTE and DCE where the rate of transmitted data is faster than the rate of received
data. Flow control is a technique for ensuring that a transmitting entity does not
overwhelm a receiving entity with data. When the buffers on the receiving device
are full, a message is sent to the sending device to suspend the transmission until
the data in the buffers has been processed.
Hardware flow control can be configured on terminal console lines (e.g. asyn0). For
Reverse Telnet connections, hardware flow control must be configured to match
on both the Access Server and the Remote Device. For terminal console sessions,
hardware flow control must be configured to match on both the DTE and the DCE.
Settings are saved in the running configuration. Changes are applied after reboot,
clear line console, or after closing the session.
Use show running-config and show startup-config commands to view hardware
flow control settings that take effect after reboot for a terminal console line. See
the show running-config command output:
Note that line configuration commands do not take effect immediately. Line
configuration commands take effect after one of the following commands or
events:
C613-50644-01 Rev B
/
)
CONSOLE
awplus#show running-config
!
line con 1
speed 9600
mode out 2001
flowcontrol hardware
!
issuing a
clear line console
issuing a
reboot
command
logging out of the current session
Command Reference for IE220 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x