Alarm Facility Loopprot Relay - Allied Telesis IE220 Series Manual

Industrial ethernet layer 2+ switches, command reference for alliedware plus version 5.5.3-0.x
Table of Contents

Advertisement

A
M
C
LARM
ONITORING
OMMANDS

ALARM FACILITY LOOPPROT RELAY

alarm facility loopprot relay
Overview
Use this command to trigger an alarm relay if the loop protection feature detects a
loop.
This will activate the device that you have connected to the switch's relay output
(for example, you could connect a buzzer to the relay output).
Use the no variant of this command to remove this alarm.
alarm facility loopprot relay
Syntax
no alarm facility loopprot relay
Default
By default, there are no alarms
Mode
Global Configuration
Usage notes
You can also use an alarm to flash the fault LED, by using the command
facility loopprot
Example
To trigger the alarm relay if loop protection detects a loop, use the commands:
awplus#
awplus(config)#
To remove that alarm, use the commands:
awplus#
awplus(config)#
Related
alarm facility loopprot led
commands
show alarm facility settings
show alarm facility status
Command
Version 5.4.9-1.1: output-member parameter added on IE510-28GSX switches
changes
C613-50644-01 Rev B
led.
configure terminal
alarm facility loopprot relay
configure terminal
no alarm facility loopprot relay
Command Reference for IE220 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
alarm
492

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ie220-6ghxIe220-10ghx

Table of Contents