alarm facility power-supply led

Overview
Use this command to make the fault LED flash if a specified power supply is not
supplying power.
Note that if both of the switch's power supplies stop supplying power, the switch's
LED will not flash, because the switch will turn off. To trigger alarms if both power
supplies go down, use the alarm relay instead
Use the no variant of this command to remove this alarm.
alarm facility power-supply <power-supply-number> led
Syntax
no alarm facility power-supply led
Default
By default, there are no alarms
Mode
Global Configuration
Usage notes
You can also use a relay to trigger an external alarm output, such as a buzzer, by
using the command
Example
To flash the LED if power supply 2 goes down, use the commands:
awplus#
awplus(config)#
To remove that alarm, use the commands:
awplus#
awplus(config)#
Related
alarm facility power-supply relay
commands
show alarm facility settings
show alarm facility status
Command
Version 5.4.9-1.1: input-member and output-member parameters added on
changes
IE510-28GSX switches
C613-50644-01 Rev B
Parameter
power-supply
<power-supply-number>
alarm facility power-supply
configure terminal
alarm facility power-supply 2 led
configure terminal
no alarm facility power-supply 2 led
Command Reference for IE220 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
(alarm facility power-supply
Description
The number of the power supply you want to monitor
with this alarm. The switch has two power supplies, so
the number is 1 or 2.
relay.
relay).