To set the device to stop shutting down the port if port1.0.5 or port1.0.6 receive
reduced power, use the commands:
awplus(config)#
awplus(config-if)#
If the device is set to send an SNMP trap for those ports, it will continue to do so.
To set the device not to perform any action when it receives reduced power on
port1.0.5 or port1.0.6, except sending a log message, use the commands:
awplus(config)#
awplus(config-if)#
Related
fiber-monitoring sensitivity
commands
show system fiber-monitoring
Command
Version 5.4.8-0.2: continuous parameter added
changes
C613-50644-01 Rev B
interface port1.0.5-port1.0.6
no fiber-monitoring action shutdown
interface port1.0.5-port1.0.6
no fiber-monitoring action