Alarm Facility Epsr Relay - Allied Telesis IE220 Series Manual

Industrial ethernet layer 2+ switches, command reference for alliedware plus version 5.5.3-0.x
Table of Contents

Advertisement

A
M
C
LARM
ONITORING
OMMANDS

ALARM FACILITY EPSR RELAY

alarm facility epsr relay
Overview
Use this command to trigger an alarm relay if EPSR detects that a link has gone
down.
This will activate the device that you have connected to the switch's relay output
(for example, you could connect a buzzer to the relay output).
Use the no variant of this command to remove this alarm.
alarm facility epsr relay
Syntax
no alarm facility epsr relay
Default
By default, there are no alarms
Mode
Global Configuration
Usage notes
You can also use an alarm to flash the fault LED, by using the command
facility epsr
Example
To trigger the alarm relay if EPSR indicates that a link has gone down, use the
commands:
awplus#
awplus(config)#
To remove that alarm, use the commands:
awplus#
awplus(config)#
Related
show alarm facility settings
commands
show alarm facility status
Command
Version 5.4.9-1.1: output-member parameter added on IE510-28GSX switches
changes
C613-50644-01 Rev B
led.
configure terminal
alarm facility epsr relay
configure terminal
no alarm facility epsr relay
Command Reference for IE220 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x