Allied Telesis IE220 Series Manual page 782

Industrial ethernet layer 2+ switches, command reference for alliedware plus version 5.5.3-0.x
Table of Contents

Advertisement

P
E
C
OWER OVER
THERNET
OMMANDS
-
SHOW POWER
INLINE
Table 1: Parameters in the show power-inline command output (cont.)
C613-50644-01 Rev B
Parameter
Actual Power
Consumption
Operational Status
Power Usage Threshold
(%)
Power Source
Power management
mode: Dynamic
High Availability
Network Power
Thermal State
Interface
Command Reference for IE220 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
Description
The current power consumption in watts (W) drawn by all
connected Powered Devices (PDs). This is updated every 5
seconds.
The operational status of the PSU hardware when this
command was issued:
• On if the PSU is installed and switched on.
• Off when the PSU is switched off (an RPS may be
connected to the switch to power PoE instead of the
PSU).
• Fault when there is an issue with the PSU hardware.
The configured SNMP trap / log threshold, as configured
from a
power-inline usage-threshold
PD (Class x) if the device is currently powered by a PD port,
or otherwise PSU.
Indicates that PoE power is allocated dynamically, based on
the current usage of each PD attached to the switch's ports.
When you connect a new PD to the switch, the switch
determines whether it can power that device by measuring
the power the existing PDs are currently using. If there is
sufficient power available, the switch will allocate it to the
new device.
Whether High Availability Network Power is enabled or
disabled globally. HANP is also known as Continuous PoE.
Continuous PoE enables the switch to perform actions such
as software upgrades without forcing the Powered Devices
to power cycle. This allows, for example, IP cameras to
buffer data instead of losing it.
Whether the switch has exceeded its safe operational
temperature and removed power from some or all ports to
limit over-heating:
• Operational means that the switch has not removed
power from any ports.
• Non-Critical Ports Denied means that the switch has
stopped supplying power to all ports except those with
a priority setting of Critical.
• All Ports Denied means that the switch has stopped
supplying power to all ports.
If the switch has stopped supplying power to any ports, it
will start supplying power again automatically when the
temperature returns to a safe level.
The PoE port(s) in the format port1.0.z, where z is the port
number. After the port number, "/D" indicates the data pair
and "/S" indicates the spare pair.
command.
782

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ie220-6ghxIe220-10ghx

Table of Contents