Allied Telesis IE220 Series Manual page 332

Industrial ethernet layer 2+ switches, command reference for alliedware plus version 5.5.3-0.x
Table of Contents

Advertisement

C
F
M
ONNECTIVITY
AULT
ANAGEMENT
MEP CROSSCHECK
An MEP can be either Up or Down for a given MD/MA, but within a bridge for the
same MD/MA, there can only be one Up or Down MEP (not both). An Up MEP must
be VLAN aware. A Down MEP may be VLAN aware. Otherwise, a Down MEP is
allowed to be link local (VLAN unaware), and its scope is that of the entire link.
Example
To create a remote MEP instance named "MA-INST2-1" with an MEP ID of 21, use
the command:
awplus(config-ether-cfm)#
MA-INST2-1
To destroy the remote MEP instance named "MA-INST2-1" with the MEP ID of 21,
use the command:
awplus(config-ether-cfm)#
MA-INST2-1
Related
cc unicast
commands
ethernet cfm domain-name
ethernet cfm mep
service ma-name
show ethernet cfm errorlog
show ethernet cfm maintenance-points remote mep
show ethernet cfm service
show mep-alarm status
Command
Version 5.4.7-1.1: command added
changes
Version 5.4.8-0.2: added to SBx8100 series products
Version 5.4.8-1.1: added to SBx908 GEN2 series products
C613-50644-01 Rev B
C
OMMANDS
in an MD/MA that is not subject to topology loops. A Down MP can be VLAN
aware or link-local.
Command Reference for IE220 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
mep crosscheck mpid 21 ma-name
no mep crosscheck mpid 21 ma-name
332

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ie220-6ghxIe220-10ghx

Table of Contents