Allied Telesis IE220 Series Manual page 357

Industrial ethernet layer 2+ switches, command reference for alliedware plus version 5.5.3-0.x
Table of Contents

Advertisement

C
F
M
ONNECTIVITY
AULT
ANAGEMENT
SHOW ETHERNET CFM SERVICE
Table 9-8: Parameters in the output from show ethernet cfm service
Related
ethernet cfm domain-name
commands
ethernet cfm mep
mep crosscheck
service ma-name
show ethernet cfm details
Command
Version 5.4.7-1.1: command added
changes
Version 5.4.8-0.2: added to SBx8100 series products
Version 5.4.8-1.1: added to SBx908 GEN2 series products
C613-50644-01 Rev B
C
OMMANDS
<ma-name> domain <domain-name> details (cont.)
Parameter
Maintenance Assoc
Name Format and
Value
CCM Transmission
Interval
Local MEPs
Configured Remote
MEPs
Missing Remote
MEPs
Defect
Command Reference for IE220 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
Description
The name and name format of the MA. The name format is
one of the following:
ICC - ICC string based name format
Integer - Integer based name format
Primary-vid - Primary VLAN based name format
String - Character string based name format
VPN-ID - VPN-ID based name format
The CCI that was configured for this MA. It can be one of
the following:
3 - CCI of 100 milliseconds
4 - CCI of 1 second (default)
5 - CCI of 10 seconds
6 - CCI of 1 minute
7 - CCI of 10 minutes
A list of the Local MEPs configured for this MA. For each
MEP, it displays the MEP direction Up or Down, its MEP-id,
and the interface it was configured on.
A list of Remote MEPs by MEP-id.
A list of the configured Remote MEPs that this MA has not
received any CCM messages from within 3.5 times the
configured CCI.
A list of defects detected by the MA's Local MEPs. The
defects shown can be:
1 - someRDIdefect is declared
2 - someMACstatusDefect is declared
3 - someRMEPCCMdefect is declared
4 - errorCCMdefect is declared
5 - xconCCMdefect is declared
357

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ie220-6ghxIe220-10ghx

Table of Contents