Alarm Facility Main-Pse Led - Allied Telesis IE220 Series Manual

Industrial ethernet layer 2+ switches, command reference for alliedware plus version 5.5.3-0.x
Table of Contents

Advertisement

A
M
C
LARM
ONITORING
OMMANDS
-
ALARM FACILITY MAIN
PSE LED

alarm facility main-pse led

Overview
Use this command to make the fault LED flash if the total power consumed by all
of the PoE devices plugged into the switch exceeds the maximum PoE output
permitted.
Use the no variant of this command to remove this alarm.
Syntax
alarm facility main-pse led
no alarm facility main-pse led
Default
By default, there are no alarms
Mode
Global Configuration
Usage notes
You can also use a relay to trigger an external alarm output, such as a buzzer, by
using the command
Example
To flash the LED if the total power consumed by all of the PoE devices plugged into
the switch exceeds the maximum PoE output permitted, use the commands:
awplus#
awplus(config)#
To remove that alarm, use the commands:
awplus#
awplus(config)#
Related
alarm facility main-pse relay
commands
show alarm facility settings
show alarm facility status
Command
Version 5.4.9-1.1: input-member and output-member parameters added on
changes
IE510-28GSX switches
C613-50644-01 Rev B
alarm facility main-pse
configure terminal
alarm facility main-pse led
configure terminal
no alarm facility main-pse led
Command Reference for IE220 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
relay.
493

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ie220-6ghxIe220-10ghx

Table of Contents