OMMANDS

ALARM FACILITY LOOPPROT LED

alarm facility loopprot led
Overview
Use this command to make the fault LED flash if the loop protection feature detects
a loop.
Use the no variant of this command to remove this alarm.
Syntax
alarm facility loopprot led
no alarm facility loopprot led
Default
By default, there are no alarms
Mode
Global Configuration
Usage notes
You can also use a relay to trigger an external alarm output, such as a buzzer, by
using the command
Example
To flash the LED if loop protection detects a loop, use the commands:
awplus#
awplus(config)#
To remove that alarm, use the commands:
awplus#
awplus(config)#
Related
alarm facility loopprot relay
commands
show alarm facility settings
show alarm facility status
Command
Version 5.4.9-1.1: output-member parameter added on IE510-28GSX switches
changes
C613-50644-01 Rev B
alarm facility loopprot
configure terminal
alarm facility loopprot led
configure terminal