AAA LOCAL AUTHENTICATION ATTEMPTS LOCKOUT
aaa local authentication attempts
lockout-time
Overview
This command configures the duration of the user lockout period.
Use the no variant of this command to restore the duration of the user lockout
period to its default of 300 seconds (5 minutes).
aaa local authentication attempts lockout-time <lockout-time>
Syntax
no aaa local authentication attempts lockout-time
Mode
Global Configuration
Default
The default for the lockout-time is 300 seconds (5 minutes).
Usage notes
While locked out all attempts to login with the locked account will fail. The lockout
can be manually cleared by another privileged account using the
user lockout
Examples
To configure the lockout period to 10 minutes (600 seconds), use the commands:
awplus#
awplus(config)#
600
To restore the default lockout period of 5 minutes (300 seconds), use the
commands:
awplus#
awplus(config)#
lockout-time
Related
aaa local authentication attempts max-fail
commands
C613-50644-01 Rev B
-
TIME
Parameter
<lockout-time>
command.
configure terminal

aaa local authentication attempts lockout-time

configure terminal
no aaa local authentication attempts
Command Reference for IE220 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
Description
<0-10000>. Time in seconds to lockout the user.