U
A
C
SER
CCESS
OMMANDS
USERNAME
Default
The privilege level is 1 by default. Note the default is not shown in running-config
output.
Usage notes
An intermediate CLI security level (privilege level 7 to privilege level 14) allows a
CLI user access to the majority of show commands, including the platform show
commands that are available at privilege level 1 to privilege level 6. Note that some
show commands, such as show running-configuration and show
startup-configuration, are only available at privilege level 15.
Examples
To create the user "bob" with a privilege level of 15, for all show commands
including show running-configuration and show startup-configuration and to
access configuration commands in Privileged Exec command mode, and the
password "bobs_secret", use the commands:
awplus#
awplus(config)#
To create a user "junior_admin" with a privilege level of 7, which will have
intermediate CLI security level access for most show commands, and the password
"show_only", use the commands:
awplus#
awplus(config)#
show_only
Related
enable password
commands
security-password minimum-categories
security-password minimum-length
C613-50644-01 Rev B
configure terminal
username bob privilege 15 password bobs_secret
configure terminal
username junior_admin privilege 7 password