ALARM FACILITY INPUT
ALARM RELAY

alarm facility input-alarm relay

Overview
Use this command to trigger an alarm relay if the input contact opens (or if it closes,
if you have used the command
closed).
This will activate the device that you have connected to the switch's relay output
(for example, you could connect a buzzer to the relay output).
Use the no variant of this command to remove this alarm.
alarm facility input-alarm 1 relay
Syntax
no alarm facility input-alarm 1 relay
Default
By default, there are no alarms
Mode
Global Configuration
Usage notes
By default, the input alarm will trigger if the input contact opens. You can change
this to closed by using the command
You can also use an alarm to flash the fault LED, by using the command
facility input-alarm
Examples
To trigger the alarm relay if the input contact opens, use the commands:
awplus#
awplus(config)#
To trigger the alarm relay if the input contact closes, use the commands:
awplus#
awplus(config)#
close
awplus(config)#
To remove that alarm, use the commands:
awplus#
awplus(config)#
Related
alarm facility input-alarm alarm-position
commands
alarm facility input-alarm led
show alarm facility settings
show alarm facility status
C613-50644-01 Rev B
Parameter
input-alarm 1
led.
configure terminal
alarm facility input-alarm 1 relay
configure terminal
alarm facility input-alarm 1 alarm-position
alarm facility input-alarm 1 relay
configure terminal
no alarm facility input-alarm 1 relay
Command Reference for IE220 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
alarm facility input-alarm alarm-position
Description
The input contact number. These switches have
one input contact, so this must be 1.
alarm facility input-alarm
to specify
alarm-position.
alarm
487