Power-Inline Disconnect-Defer - Allied Telesis IE220 Series Manual

Industrial ethernet layer 2+ switches, command reference for alliedware plus version 5.5.3-0.x
Table of Contents

Advertisement

P
E
C
OWER OVER
THERNET
OMMANDS
-
-
POWER
INLINE DISCONNECT
DEFER

power-inline disconnect-defer

Overview
Use this command to defer the DC disconnect detection in hardware. Some 60W
PDs take longer than the 802.3 at standard time for drawing the minimum DC
current on an individual pair. By deferring the enabling of the DC disconnect logic,
both sets of pairs can power up and start drawing current.
Use the optional timeout value when non-standard PDs, such as FLIR (Forward
Looking InfraRed) cameras are used.
Use the no variant of this command to revert to the default setting.
power-inline disconnect-defer [<disconnect-defer-timeout>]
Syntax
no power-inline disconnect-defer
Default
Disabled
Mode
Interface Configuration
Example
Related
show power-inline
commands
Command
Version 5.5.0-2.3: command added
changes
Version 5.5.1-1.1: added disconnect-defer-timeout parameter
C613-50644-01 Rev B
Parameter
<disconnect-defer-timeout>
Command Reference for IE220 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
Description
Optional timeout value of 1-10s