Loop-Protection Timeout - Allied Telesis IE220 Series Manual

Industrial ethernet layer 2+ switches, command reference for alliedware plus version 5.5.3-0.x
Table of Contents

Advertisement

S
C
WITCHING
OMMANDS
-
LOOP
PROTECTION TIMEOUT

loop-protection timeout

Overview
Use this command to specify the Loop Protection recovery action duration on an
interface.
Use the no variant of this command to set the loop protection timeout to the
default.
Syntax
loop-protection timeout <duration>
no loop-protection timeout
Default
The default is 7 seconds.
Mode
Interface Configuration
Usage notes
See the "Loop Protection" section in the
Configuration_Guide
information prior to applying this command.
Example
To configure a loop protection action timeout of 10 seconds for port1.0.4, use the
command:
awplus#
awplus(config)#
awplus(config-if)#
Related
loop-protection loop-detect
commands
loop-protection action
show loop-protection
C613-50644-01 Rev B
Parameter
Description
<duration>
The time (in seconds) for which the configured action will apply
before being disabled. This duration can be set between 0 and 86400
seconds (24 hours). The set of 0 means infinity so timeout does not
expire.
for relevant conceptual, configuration, and overview
configure terminal
interface port1.0.4
Command Reference for IE220 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
Switching_Feature Overview_and
loop-protection timeout 10