Chapter 9 Warning and Fault CodesEB3000
Abbreviated
ID No.
Warning Code
5
CE10
Action condition
Action time
Warning treatment
parameter
Reset method
Reset condition
Record
Cause
Incorrect communication
command from elevator
controller
Malfunction caused by
interference
Different communication
setting from the elevator
controller
Disconnection or bad
connection of the cable
Abbreviated
ID No.
Warning Code
6
CP10
Action condition
Action time
Warning treatment
parameter
Reset method
Reset condition
Record
Cause
Disconnection or bad
connection of the cable
Digital keypad malfunction Replace the digital keypad
Display on
Warning Name
KPED-LE02
Communication error 10 Modbus transmission time-out
Action and Reset
N/A
When communication time exceeds the detection time of Pr.04-61
Pr.04-60 (Default: 3)
0: Warn and keep operation
1: Fault and ramp to stop
2: Reserved
3: No action and no display
Auto
When Pr.04-60=0, cE10 is a warning and will be automatically cleared.
Manual When Pr.04-60=1, cE10 is a fault and must be reset manually.
N/A
If cE10 is a warning, it will not be recorded.
If cE10 is a fault, it will be recorded.
Check if the communication command is correct.
Verify the wiring and grounding of the communication circuit. It is recommended to
separate the communication circuit from the main circuit, or wire in 90 degree for
effective anti-interference performance.
Check if the setting for Pr.09-00–Pr.09-02 is the same as the setting for the elevator
controller.
Check the cable and replace it if necessary.
Display on
Warning Name
KPED-LE02
Digital keypad
transmission time-out
Action and Reset
N/A
When communication time exceeds Pr.04-63
Pr.04-62 (Default: 3)
0: Warn and keep operation
1: Fault and ramp to stop
2: Fault and coast to stop
3: No action and no display
Auto
When Pr.04-62=0, cP10 is a warning and will be automatically cleared.
Manual When Pr.04-62=1 or 2, cP10 is a fault and must be reset manually.
N/A
If cP10 is a warning, it will not be recorded.
If cP10 is a fault, it will be recorded.
Check the cable and replace it if necessary.
Corrective Actions
Communication time-out for digital keypad
KPC-CC01
Corrective Actions
9-6
Description
Description
<Go to
List of Warning
Codes>